Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Journal of Zhejiang University. Medical sciences ; (6): 195-206, 2023.
Article in English | WPRIM | ID: wpr-982035

ABSTRACT

OBJECTIVES@#To detect the contents of Tangwei capsule main components with high performance liquid chromatography-quantitative analysis of multicomponents by single marker (HPLC-QAMS) method and to evaluate the quality with chemometrics and entropy weight-technique for order preference by similarity to an ideal solution (EW-TOPSIS).@*METHODS@#A symmetry C18 column and 0.1% formic acid-acetonitrile as mobile phase were used for HPLC of Tangwei capsule. The contents of 3'-hydroxypuerarin, puerarin, 3'-methoxypuerarin, methylnissolin-3-O-glucoside, calycosin, formononetin, rosmarinic acid, salvianolic acid B, dihydrotanshinone Ⅰ, cryptotanshinone, tanshinone Ⅰ, tanshinone ⅡA and cucurbitacin B in 15 batches of Tangwei capsule were determined simultaneously. The quality differences of 15 batches of samples were analyzed by chemometrics and EW-TOPSIS.@*RESULTS@#The HPLC-UV showed that 13 components had good linear relationships in corresponding concentration ranges (r≥0.9991). The relative standard deviations (RSD) of precision, repeatability and stability were all less than 2.00%. The average recovery rates were between 96.86% and 100.13%, and RSD were all less than 2.00%. Cluster analysis showed that 15 batches of samples were clustered into 3 groups. Partial least squares-discriminant analysis showed that salvianolic acid B, formononetin, puerarin, 3'-methoxypuerarin and rosmarinic acid were the main potential markers affecting the quality of Tangwei capsule. EW-TOPSIS analysis showed that the quality of S12-S15 was superior.@*CONCLUSIONS@#The analytical method established in this study can be used for the comprehensive evaluation of the quality of Tangwei capsule to provide laboratory support for its quality control and overall evaluation.


Subject(s)
Drugs, Chinese Herbal , Chromatography, High Pressure Liquid/methods , Chemometrics , Entropy
2.
International Journal of Traditional Chinese Medicine ; (6): 1226-1233, 2021.
Article in Chinese | WPRIM | ID: wpr-907700

ABSTRACT

Objective:To determine the content of albiflorin, paeoniflorin, benzoylpaeoniflorin, sophoricoside, prim-O-glucosylcimifugin, cimifugin, 5-O-methylvisammioside and sec-O-glucosylhamaudol in Huaiqin Salve with high performance liquid chromatography-quantitative analysis of multi-components by single-marker (HPLC-QAMS) method. Methods:The samples were separated with ZORBAX Eclipse XDB-C18 column by a gradient elution using methanol-acetonitrile (1:2) (A)-0.1% phosphoric acid solution (B) as mobile phase and the flow rate was 1.0 ml/min. The detection wavelength was 230 nm for albiflorin, paeoniflorin and benzoylpaeoniflorin, and 254 nm for sophoricoside, prim-O-glucosylcimifugin, cimifugin, 5-O-methylvisammioside and sec-O-glucosylhamaudol. The column temperature was 30 ℃. Using sophoricoside as an internal standard, the relative correction factors (RCFs) of albiflorin, paeoniflorin, benzoylpaeoniflorin, prim-O-glucosylcimifugin, cimifugin, 5-O-methylvisammioside and sec-O-glucosylhamaudol were calculated. The method was validated by comparison of the quantitative results between external standard method (ESM) and HPLC-QAMS method.Results:Albiflorin, paeoniflorin, benzoylpaeoniflorin, sophoricoside, prim-O-glucosylcimifugin, cimifugin, 5-O-methylvisammioside and sec-O-glucosylhamaudol showed good linear relationship within the range of 0.034 7-0.867 5, 0.063 6-1.590 0, 0.006 9-0.172 5, 0.198 6-4.965 0, 0.092 8-2.320 0, 0.026 6-0.665 0, 0.042 7-1.067 5, 0.020 9-0.522 5 μg ( r ≥ 0.999 1); whose average recoveries ( RSDs) were 98.85% (1.02%), 100.04% (0.67%), 96.92% (1.14%), 100.06% (0.85%), 99.31% (1.39%), 99.16% (1.22%), 98.59% (1.33%) and 97.58% (1.41%), respectively. No significant differences were found in the quantitative analysis of the components with ESM and HPLC-QAMS method. Conclusion:The HPLC-QAMS method could provide the reference for themulti-index component evaluation for Huaiqin Salve.

3.
Braz. j. pharm. sci ; 52(1): 87-94, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-789079

ABSTRACT

ABSTRACT The present work describes the development of a new high performance liquid chromatographic (HPLC) method for the determination of Cefixime trihydrate under different stress conditons as specified by ICH. For the analysis, a Phenomenex (250 x 4.6 mm, 5 µm particle size) ODS column and a SPD 20 A UV detector at 289 nm was used. The selected mobile phase was 10 mM disodium hydrogen phosphate (with 0.5% TEA, pH adjusted to 6.3 with OPA) and methanol in the ratio of 75:25 (v/v) in isocratic mode at a flow rate of 1 mL.min-1.The linear regression analysis data for the calibration plots showed good linear relationship with r2 = 0.9997 in the concentration range of 5-100 μg.mL-1. The stress degradation was performed using acid, alkali, water, hydrogen peroxide and uv light.


RESUMO O presente trabalho descreve o desenvolvimento de um novo alta performance cromatografia líquida (HPLC) método para a determinação de cefixima tri-estresse sob diferentes condições, conforme especificado pelo ICH. Para a análise, a Phenomenex (250 x 4,6 mm, 5 µm de granulometria) ODS coluna e a SPD 20 um detector de UV em 289 nm foi utilizado. A fase móvel selecionado foi de 10 mM hidrogenofosfato dissódico (com 0,5% TEA, o pH ajustado para 6,3 com OPA) e de metanol em razão de 75:25 (v/v) no modo isocrático com uma taxa de fluxo de 1 mL.min-1. A análise de regressão linear para dados da calibração parcelas apresentaram boa relação linear com r2 = 0,9997 no intervalo de concentração de cerca de 5 100 µg.mL-1. Degradação do estresse foi realizado utilizando um ácido, alcalino, a água, o peróxido de hidrogênio e luz uv.


Subject(s)
Chromatography, High Pressure Liquid/methods , Cefixime/analysis , Metabolism , /methods , Microscopy, Ultraviolet/methods
4.
Braz. j. pharm. sci ; 51(4): 879-891, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778404

ABSTRACT

abstract The antiparkinson agent pramipexole dihydrochloride monohydrate was quantified in pharmaceutical products by high performance liquid chromatography (HPLC) and derivative spectrophotometry. The first method was based on HPLC using tamsulosin HCl as an internal standard. In this method, chromatographic separation was achieved using a LiChrospher 60 RP column at 25°C, with a flow rate of 1.0 mL/min at 263 nm. The eluent comprised 0.01 mol/L ammonium acetate (pH 4.4) and acetonitrile (35:65 by volume). The linearity range was found to be 10.0-30.0 µg/mL with a mean recovery of 100.5 ± 1.10. The limit of detection (8 ng/mL) and limit of quantification (50 ng/mL) were calculated. In the second method, the first derivative spectrophotometric technique for the determination of pramipexole dihydrochloride monohydrate was performed by measuring the amplitude at 249 and 280 nm. In the first derivative technique, the absorbance and concentration plot was rectilinear over the 5.0-35.0 µg/mL range with a lower detection limit of 1.5 ng/mL and quantification limit of 4.5 ng/mL. The typical excipients included in the pharmaceutical product do not interfere with the selectivity of either method. The developed methods were validated for robustness, selectivity, specificity, linearity, precision, and accuracy as per the ICH and FDA guidelines (ICH Q2B, 1996; FDA,2000). In conclusion, the developed methods were successful in determining the quantity of the antiparkinson agent pramipexole dihydrochloride monohydrate in pharmaceutical products. The RSD values for the pharmaceutical product used in this study were found to be 0.97% for the HPLC method and 0.00% for the first derivative spectrophotometric method.


resumo O fármaco antiparkinsoniano, dicloridrato de pramipexol monoidratado, foi quantificado no produto farmacêutico por cromatografia líquida de alta eficiência (CLAE) e espectrofotometria derivada. No primeiro método baseado na CLAE, o cloridrato de tansulosina foi usado como padrão interno. Nesse método, a separação cromatográfica foi realizada usando uma coluna Lichrosper 60 RP a 25 °C e acetato de amônio 0,01 mol/L (pH:4.4): acetonitrila (35:65 em volume) como eluente com fluxo de 1,0 mL /min a 263 nm. A faixa de linearidade foi de 10.0-30.0 µg/mL com média da recuperação 100.5 ± 1.10. O limite de detecção (8 ng/mL) e o limite de quantificação (50 ng/mL) foram calculados. Por outro lado, a primeira técnica de espectrofotometria derivada para a determinação de dicloridrato de pramipexol monoidratado foi realizada através da medida da amplitude a 249 e 280 nm. Na técnia da primeira derivada, a absorvância e a plotagem da concentração foi retilínea na faixa de 5.0-35.0 µg/mL com limite inferior de detecção de 1.5 ng/mL e limite de quantificação de 4.5 ng/mL. Os excipientes típicos incluídos no produto farmacêutico não interferem com a seletividade dos métodos. Os métodos desenvolvidos foram validados quanto à robustez, seletividade, especificidade, linearidade, precisão e exatidão de acordo com as diretrizes do ICH e FDA (ICH Q2B,1996; FDA,2000). Concluindo, os métodos propostos foram aplicados com sucesso para a determinação quantitativa do agente antiparkinsoniano dicloridrato de pramipexol monoidrato em produtos farmacêuticos. Os valores de RSD para o produto farmacêutico utilizado neste estudo foi 0.97% para a CLAE e 0.00% para o método de espectrofotometria de primeira derivada.


Subject(s)
Pharmaceutical Preparations , Chromatography, High Pressure Liquid/methods , Antiparkinson Agents/analysis , Spectrophotometry
5.
Braz. j. pharm. sci ; 51(4): 823-832, Oct.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-778418

ABSTRACT

abstract A method to ensure that an analytical method will produce reliable and interpretable information about the sample must first be validated, making sure that the results can be trusted and traced. In this study, we propose to validate an analytical high performance liquid chromatography (HPLC) method for the quantitation of meloxicam loaded PEGylated nanocapsules(M-PEGNC). We performed a validation study, evaluated parameters including specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. PEGylated nanocapsules were prepared by interfacial deposition of preformed polymer, and the particle size, polydispersity index, zeta potential, pH value and encapsulation efficiency were characterized. The proposed HPLC method provides selective, linear results in the range of 1.0-40.0 μg/mL; quantification and detection limits were 1.78 μg/mL and 0.59 μg/mL, respectively; relative standard deviation for repeatability was 1.35% and intermediate precision was 0.41% and 0.61% for analyst 1 and analyst 2, respectively; accuracy between 99.23 and 101.79%; robustness between 97.13 and 98.45% for the quantification of M-PEGNC. Mean particle diameters were 261 ± 13 nm and 249 ± 20 nm, polydispersity index was 0.15 ± 0.07 and 0.17 ± 0.06, pH values were 5.0 ± 0.2 and 5.2 ± 0.1, and zeta-potential values were -37.9 ± 3.2 mV e -31.8 ± 2.8 mV for M-PEGNC and placebo(B-PEGNC), respectively. In conclusion, the proposed analytical method is suitable for the quality control of M-PEGNC. Moreover, suspensions showed monomodal size distributions and low polydispersity index indicating high homogeneity of formulations with narrow size distributions, and appropriate pH and zeta potential. The extraction process was efficient for release of meloxicam from nanostructured systems.


resumo Para se assegurar que um método analítico produzirá informação confiável e interpretável sobre a amostra este deve ser inicialmente validado, tornando claro que os resultados podem ser confiados e rastreados. Neste estudo, propomos validar um método de cromatografia líquida de alta eficiência (CLAE) para a quantificação do meloxicam encapsulado em nanocápsulas PEGuiladas (M-PEGNC). Efetuamos a validação, avaliando parâmetros de especificidade, linearidade, limite de quantificação, limite de detecção, exatidão, precisão e robustez. As nanocápsulas PEGuiladas foram preparadas por deposição interfacial do polímero pré-formado e caracterizaram-se o tamanho da partícula, índice de polidispersão, potencial zeta, pH e eficiência de encapsulação. O método de CLAE proposto fornece resultados seletivos e lineares na faixa de 1,0-40,0 mg/mL; limites de quantificação e detecção de 1,78 mg/mL e 0,59 mg/mL, respectivamente; desvio padrão relativo para a repetibilidade de 1,35% e precisão intermediária de 0,41% e 0,61% para o analista 1 e analista 2, respectivamente; exatidão entre 99,23 e 101,79%; robustez entre 97,13 e 98,45% para a quantificação de M-PEGNC. Os diâmetros médios das partículas foram 261 ± 13 nm e 249 ± 20 nm; índice de polidispersão de 0,15 ± 0,07 e 0,17 ± 0,06, valores de pH de 5,0 ± 0,2 e 5,2 ± 0,1 e valores do potencial zeta de -37,9 ± 3,2 mV e -31,8 ± 2,8 mV para o M-PEGNC e o placebo(B-PEGNC), respectivamente. Concluindo, o método analítico proposto é adequado para o controle de qualidade do M-PEGNC. Além disso, suspensões mostraram distribuição de tamanho monomodal e baixo índice de polidispersão, indicando alta homogeneidade das formulações com distribuição estreita de tamanho, pH e potencial zeta apropriados. O processo de extração foi eficiente para a liberação do meloxicam dos sistemas nanoestruturados.


Subject(s)
Chromatography, High Pressure Liquid/methods , Nanocapsules , Polyethylene Glycols , Quality Control , Nanoparticles/analysis
6.
Braz. j. pharm. sci ; 51(2): 349-360, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755049

ABSTRACT

Three methods are proposed for the quantitative determination of raloxifene hydrochloride in pharmaceutical dosage form: ultraviolet method (UV) high performance liquid chromatography (HPLC) and micellar capillary electrophoresis (MEKC). These methods were developed and validated and showed good linearity, precision and accuracy. Also they demonstrated to be specific and robust. The HPLC and MEKC methods were tested in regards to be stability indicating methods and they showed to have this attribute. The UV method used methanol as solvent and optimal wavelength at 284 nm, obeying Lambert-Beer law in these conditions. The chromatographic conditions for the HPLC method included: NST column C18 (250 x 4.6 mm x 5 µm), mobile phase water:acetonitrile:triethylamine (67:33:0,3 v/v), pH 3.5, flow rate 1.0 mL min-1, injection volume 20.0 µl, UV detection 287 nm and analysis temperature 30 °C. The MEKC method was performed on a fused-silica capillary (40 cm effective length x 50 µm i.d.) using as background electrolyte 35.0 mmol L-1 borate buffer and 50.0 mmol L-1 anionic detergent sodium dodecyl sulfate (SDS) at pH 8.8. The capillary temperature was 32°C, applied voltage 25 kV, UV detection at 280 nm and injection was perfomed at 45 mBar for 4 s, hydrodimanic mode. In this MEKC method, potassium diclofenac (200.0 µg mL-1) was used as internal standard. All these methods were statistically analyzed and demonstrated to be equivalent for quantitative analysis of RLX in tablets and were successfully applied for the determination of the drug...


Três métodos são propostos para a quantificação de cloridrato de raloxifeno em sua forma farmacêutica de comprimidos: espectrofotometria no ultravioleta (UV), cromatografia líquida de alta eficiência (HPLC) e eletroforese capilar micelar (MEKC). Estes métodos desenvolvidos e validados demonstraram linearidade, precisão e exatidão. Também foram específicos e robustos. Os métodos HPLC e MEKC foram desenvolvidos para indicar a estabilidade do fármaco e demonstraram ter este atributo. O método UV usou metanol como solvente e comprimento de onda de 284nm, obedecendo a Lei de Lambert-Beer nestas condições. Os parâmetros cromatográficos para o método HPLC foram: coluna NST C18 (250 x 4,6 mm x 5 µm), fase móvel composta de água:acetonitrila:trietilamina (67:33:0,3 v/v), pH 3,5, vazão da fase móvel de 1,0 mL min-1, volume de injeção de 20 µl, detecção no comprimento de onda de 287 nm e temperatura de análise de 30°C. O método MEKC foi realizado utilizando capilar de sílica fundida (40 cm de comprimento efetivo x 50 µm de diâmetro interno) usando como fase móvel solução tampão borato 35.0 mmol L-1 e solução de dodecil sulfato de sódio (SDS) 50.0 mmol L-1 pH 8,8. A temperatura de análise foi de 32 °C, com voltagem aplicada de 25 kV, detecção no comprimento de onda de 280 nm e injeção da amostra realizada a 45 mBar por 4 s em modo hidrodinâmico. Para este método MEKC, foi utilizado diclofenaco de potássio (200.0 µg mL-1) como padrão interno. Todos os métodos foram analisados estatisticamente e demostraram ser equivalentes para a análise quantitativa de raloxifeno em comprimidos e foram aplicados com sucesso na determinação do fármaco...


Subject(s)
Humans , Raloxifene Hydrochloride/analysis , Raloxifene Hydrochloride/pharmacology , Drug Compounding/methods , Drug Stability , Chromatography, High Pressure Liquid/methods , Electrophoresis, Capillary/methods , Spectrum Analysis/methods
7.
Braz. j. pharm. sci ; 51(2): 361-366, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755061

ABSTRACT

The hemoglobinopathies are included among the most common genetic diseases in the world. In Brazil, hemoglobinopathies are related to the diversity of racial backgrounds and the degree of interbreeding. The study focused on the prevalence of hemoglobinopathies using conventional and confirmatory laboratory tests in children from public schools in Ribeirão Preto-SP. The study involved the participation of 427 children between six and nine years of age. Hematologic evaluation, hemoglobin electrophoresis on cellulose acetate at alkaline pH, quantification of hemoglobin fractions by high performance liquid chromatography (HPLC) and detection of -α3.7 deletion for α thalassemia by polymerase chain reaction were performed. The results of hemoglobin electrophoresis on cellulose acetate and HPLC of the children studied showed the presence of 30 children (7%) with hemoglobinopathies. Eleven children presented results indicating suspicion of S/β-thalassemia; their parents and/or siblings were evaluated and confirmed the presence of only Hb S. The analysis of deletion -α3.7to characterize α-thalassemias sampling performed on 207 participants identified 26 children (12.6%) with deletion -α3.7. Thus, 54 (12.6%) of the children studied present this genetic alteration. For the detection of α-thalassemias it is necessary to use confirmatory methods such as molecular analysis and evaluation of family members in doubtful cases to facilitate genetic counseling in families, in which deletion -α3.7 is more frequent in Brazil...


As hemoglobinopatias estão incluídas nas doenças genéticas mais comuns no mundo. No Brasil, as hemoglobinopatias são relatadas pela diversidade racial e o grau de miscigenação. O estudo focou a prevalência das hemoglobinopatias usando métodos laboratoriais convencionais como a eletroforese de hemoglobina em acetato de celulose em pH alcalino e confirmatório por reação em cadeia de polimerase (PCR) em crianças de escolas públicas de Ribeirão Preto-SP. O estudo envolveu a participação de 427 crianças entre 6-9 anos de idade. Determinaram-se os valores hematológicos, efetuou-se eletroforese de hemoglobina em acetato de celulose em pH alcalino, quantificação das frações de hemoglobina por HPLC e a detecção da deleção -α3,7 pela PCR. Os resultados da eletroforese de hemoglobina em acetato de celulose e do HPLC, nas crianças estudadas, mostraram a presença de 30 crianças (7%) com hemoglobinopatias. Onze crianças apresentaram resultado indicando a suspeita de S/β-talassemia; seus pais e/ou irmãos confirmaram a presença de apenas a Hb S. A análise da deleção -α3,7, uma das alterações que estão presentes na α-talassemia, realizada em 207 participantes, identificou 26 crianças (12,6%) com a deleção -α3,7. Dessa forma, 54 (12,6%) das crianças estudadas apresentam hemoglobinopatias. Para a deleção da α-talassemias é necessário utilizar métodos confirmatórios como as análises moleculares e avaliação de membros da família, em casos duvidosos, facilitando o aconselhamento genético nas famílias, sendo a deleção -α3,7 mais frequente no Brasil...


Subject(s)
Humans , Male , Female , Child , Blood Protein Electrophoresis , Hemoglobinopathies , Chromatography, High Pressure Liquid/statistics & numerical data , Hemoglobins/analysis , Polymerase Chain Reaction/statistics & numerical data , Hematologic Tests/methods , Hematologic Tests
8.
Braz. j. pharm. sci ; 51(2): 461-466, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755065

ABSTRACT

Saxagliptin is a potent and selective inhibitor of the enzyme dipeptidyl peptidase 4. It is effective in the treatment of type 2 diabetes mellitus because it stimulates the pancreas to produce insulin. In the present study, a liquid chromatography method was developed and validated to quantify the drug in tablets. This method was based on the isocratic elution of saxagliptin, using a mobile phase consisting of 0.1% phosphoric acid at pH 3.0 - methanol (70: 30, v/v) at a flow rate of 1 mL.min-1 with UV detection at 225 nm. The chromatographic separation was achieved in 8 minutes on a Waters XBridge C18 column (250 mm x 4.6 mm, 5µm) maintained at ambient temperature. The proposed method proved to be specific and robust for the quality control of saxagliptin in pharmaceutical dosage forms, showing good linearity in the range of 15.0 - 100.0 µg.mL-1 (r>0.999), precision (RSD<1.49%) and accuracy values between 99.42 and 101.59%. The method was found to be stability indicating and was successfully applied for the analysis of saxagliptin in tablets in a routine quality control laboratory...


A saxagliptina é uma inibidora potente e seletiva da enzima dipeptidil peptidase 4. É efetiva no tratamento do Diabete mellitus tipo 2, pois estimula a produção de insulina pelo pâncreas. No presente estudo, desenvolveu-se e validou-se método por cromatografia líquida de alta eficiência para quantificar o fármaco em comprimidos. O método foi baseado em eluição isocrática, utilizando fase móvel constituída por ácido fosfórico 0,1% pH 3,0-metanol (70 : 30, v/v), fluxo de 1,0 mL.min-1, com detecção UV em 225 nm. A separação cromatográfica foi alcançada em 8 minutos em coluna Waters XBridge C18 (250 mm x 4,6 mm, 5 µm) mantida à temperatura ambiente. O método proposto mostrou-se específico e robusto para o controle de qualidade de saxagliptina em comprimidos, sendo linear na faixa de concentração de 15,0-100,0 µg.mL-1 (r>0,999), preciso (RSD<1,49%) e exato, com resultados entre 99,42 e 101,59%. O método mostrou-se indicativo de estabilidade e foi aplicado com sucesso no controle de qualidade de saxagliptina em comprimidos...


Subject(s)
Humans , Drug Compounding/methods , Chromatography, Liquid/methods , Diabetes Mellitus/drug therapy , Enzyme Inhibitors/pharmacology , Clinical Chemistry Tests/methods
9.
Braz. j. pharm. sci ; 51(2): 305-315, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755067

ABSTRACT

A bioanalytical method was developed and applied to quantify the free imipenem concentrations for pharmacokinetics and PK/PD correlation studies of the dose adjustments required to maintain antimicrobial effectiveness in pediatric burn patients. A reverse-phase Supelcosil LC18 column (250 x 4.6 mm 5 micra), binary mobile phase consisting of 0.01 M, pH 7.0 phosphate buffer and acetonitrile (99:1, v/v), flow rate of 0.8 mL/min, was applied. The method showed good absolute recovery (above 90%), good linearity (0.25-100.0 µg/mL, r2=0.999), good sensitivity (LLOQ: 0.25 µg/mL; LLOD: 0.12 µg/mL) and acceptable stability. Inter/intraday precision values were 7.3/5.9%, and mean accuracy was 92.9%. A bioanalytical method was applied to quantify free drug concentrations in children with burns. Six pediatric burn patients (median 7.0 years old, 27.5 kg), normal renal function, and 33% total burn surface area were prospectively investigated; inhalation injuries were present in 4/6 (67%) of the patients. Plasma monitoring and PK assessments were performed using a serial blood sample collection for each set, totaling 10 sets. The PK/PD target attained (40%T>MIC) for each minimum inhibitory concentration (MIC: 0.5, 1.0, 2.0, 4.0 mg/L) occurred at a percentage higher than 80% of the sets investigated and 100% after dose adjustment. In conclusion, the purification of plasma samples using an ultrafiltration technique followed by quantification of imipenem plasma measurements using the LC method is quite simple, useful, and requires small volumes for blood sampling. In addition, a small amount of plasma (0.25 mL) is needed to guarantee drug effectiveness in pediatric burn patients. There is also a low risk of neurotoxicity, which is important because pharmacokinetics are unpredictable in these critical patients with severe hospital infection. Finally, the PK/PD target was attained for imipenem in the control of sepsis in pediatric patients...


Desenvolveu-se e aplicou-se método bioanalítico para quantificar concentrações de imipenem livre para estudos de farmacocinética (PK) e de correlação PK/PD dos ajustes de dose requeridos para manter a efetividade antimicrobiana em pacientes pediátricos queimados. Utilizou-se coluna Supelcosil LC18 (250 x 4,6 mm 5 micra), fase móvel binária, consistindo de tampão fosfato 0,01M pH 7,0 e acetonitrila (99:1, v/v) e fluxo de 0,8 mL/min. O método mostrou boa recuperação absoluta (acima de 90%), boa linearidade (0,25-100,0 µg/mL, r2=0.999), boa sensibilidade (LLOQ: 0,25 µg/mL; LLOD: 0,12 µg/mL) e estabilidade aceitável. Os valores de precisão inter/intradia foram 7,3/5,9% e a exatidão média foi de 92,9%. O método bioanalítico foi aplicado para quantificar concentrações de fármaco livre em crianças com queimaduras, Seis pacientes pediátricos queimados (idade média de 7,0 anos, 27,5 kg), com função renal normal e 33% da superfície total queimada foram investigados prospectivamente. Lesões por inalação estavam presentes em 4/6 (67%) dos pacientes. O monitoramento plasmático e a as avaliações de PK foram efetuadas utilizando coleção de amostras seriais de sangue para cada série, totalizando 10 conjuntos. O alvo PK/PD alcançado (40%T>MIC) para cada concentração inibitória mínima (MIC: 0,5, 1,0, 2,0, 4,0 mg/L) ocorreu em porcentagem maior do que 80% dos conjuntos investigados e 100% após o ajuste de dose. Em conclusão, a purificação das amostras do plasma usando técnica de ultrafiltração seguida de quantificação das medidas do imipenem no plasma usando método de cromatografia líquida é bastante simples, útil e necessita de pequenos volumes para as amostras de sangue. Além disso, pequena quantidade de plasma (0,25 mL) é necessário para garantir a efetividade do fármaco nos pacientes pediátricos queimados. Há, ainda, baixo risco de neurotoxicidade, o que é importante, visto que as farmacocinéticas são imprevisíveis nesses pacientes...


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Chromatography, Liquid/methods , Imipenem/analysis , Imipenem/blood , Clinical Chemistry Tests/methods , Anti-Bacterial Agents/pharmacokinetics , Anti-Bacterial Agents/pharmacology , Burn Units
10.
Braz. j. pharm. sci ; 50(3): 551-557, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-728691

ABSTRACT

A simple and environmentally friendly microextraction technique was used for determination of chlorpheniramine (CPM), an antihistamine drug, in human urine samples using dispersive liquid-liquid microextraction (DLLME) followed by high performance liquid chromatography with diode array detection (HPLC-DAD). In this extraction technique, an appropriate mixture of acetonitrile (disperser solvent) and carbon tetrachloride (extraction solvent) was rapidly injected into the urine sample containing the target analyte. Tiny droplets of extractant were formed and dispersed into the sample solution and then sedimented at the bottom of the conical test tube by centrifugation. Under optimal conditions, the calibration curve was linear in the range of 0.055-5.5 µg mL-1, with a detection limit of 16.5 ng mL-1. This proposed method was successfully applied to the analysis of real urine samples. Low consumption of toxic organic solvents, simplicity of operation, low cost and acceptable figures of merit are the main advantages of the proposed technique.


Utilizou-se uma técnica de microextração simples e ambientalmente amigável para a determinação de clorfeniramina (CPM), anti-histamínico, em amostras de urina humana, utilizando a microextração dispersiva líquido-líquido (DLLME), seguida por cromatografia líquida de alta eficiência com detecção por arranjo de diodos (HPLC-DAD). Nesse método de extração, mistura apropriada de acetonitrila (solvente dispersor) e tetracloreto de carbono (solvente de extração) foi injetada rapidamente na amostra de urina contendo o analito alvo. As pequenas gotículas de agente de extração foram formadas e dispersas na solução da amostra e, em seguida, sedimentadas no fundo do tubo cônico de ensaio por centrifugação. Em condições ótimas, a curva de calibração foi linear no intervalo entre 0,055 e 5,5 µg mL-1, com limite de detecção de 16,5 ng mL-1. O método proposto foi aplicado com sucesso na análise de amostras de urina reais. Baixo consumo de solventes orgânicos tóxicos, simplicidade de operação, baixo custo e figuras de mérito aceitáveis são as principais vantagens do método sugerido.


Subject(s)
Chlorpheniramine/analysis , Chromatography, Liquid/methods , Urine Specimen Collection , Liquid Phase Microextraction/methods , /analysis , Histamine Antagonists/analysis
11.
Braz. j. pharm. sci ; 50(3): 629-638, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-728700

ABSTRACT

A viable cost-effective and isocratic approach employing C-18 column (250 mm × 4.6 mm, 5 µm) based HPLC has been utilized to separate and estimate the drugs, rosuvastatin, amlodipine and their stress induced degradation products, simultaneously in pharmaceutical formulations. Focused on ICH guideline parameters, the efficient separation of both drugs and their degradation products was achieved by optimizing a 30:70 (v/v) solvent mixture of acetonitrile and 0.1 M ammonium acetate buffer (pH 5) as mobile phase. The flow rate of the mobile phase was 1.5 mL/min and all the detections were carried out at 240 nm using UV detector. The method was linear in the concentration range of 1-200 µg/mL for rosuvastatin with 0.996 coefficient of determination value. For amlodipine, linearity was in the range of 0.5-100 µg/ml with 0.994 coefficient of determination value. Both the drugs along with their degradation products were separated in less than twenty minutes. The results of within-day and between-day precision were varied from 0.72 to 1.81% for rosuvastatin and 0.83 to 1.88% for amlodipine. The results show that this ICH validated method can be employed successfully for the routine as well as stability quantification of both the active ingredients simultaneously in pharmaceutical formulations.


Utilizou-se abordagem de viabilidade custo-efetividade e isocrática, baseada em CLAE, empregando coluna C-18 (250 mm x 4,6 mm, 5 µm) para separar e avaliar os fármacos, rosuvastatina, anlodipino e seus produtos de degradação induzida por estresse, simultaneamente, em formulações farmacêuticas. Focada nos parâmetros das diretrizes da ICH, a separação eficiente de ambos os fármacos e de seus produtos de degradação foi obtida por meio da otimização da fase móvel com mistura de solventes 30:70 (v/v), respectivamente, acetonitrila e tampão acetato de amônio O,1 M (pH 5). A velocidade de fluxo da fase móvel foi de 1,5 mL/min e todas as detecções foram realizadas em 240 nm, utilizando detector de UV. O método foi linear no intervalo de concentração de 1-200 µg/mL para a rosuvastatina com coeficiente de determinação 0,996. Para o anlodipino, a linearidade ficou na faixa de 0.5-100 µg/mL, com coeficiente de determinação 0,994. Ambos os fármacos, junto com seus produtos de degradação, foram separados em menos de vinte minutos. Os resultados de precisão intra-dia e inter-dia variaram de 0,72 a 1,81% para a rosuvastatina e de 0,83 a 1,88%, para o anlodipino. Os resultados mostram que este método validado pelo ICH pode ser empregado com sucesso tanto para a rotina quanto para a quantificação simultânea da estabilidade de ambos os ingredientes ativos em formulações farmacêuticas.


Subject(s)
Chemistry, Pharmaceutical/classification , Chromatography, High Pressure Liquid/methods , Amlodipine/analysis , Rosuvastatin Calcium/analysis , Acetonitriles/analysis
12.
Braz. j. pharm. sci ; 50(4): 895-901, Oct-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-741340

ABSTRACT

A simple, specific, precise, accurate, linear, rapid, economic and validated stability indicating an RP-HPLC method for the simultaneous quantification of cefepime and tazobactam in a dry injection dosage form has been developed. Separation was performed on a 5 µm ACE C18 column with phosphate buffer, pH adjusted to 4.5 with phosphoric acid: methanol (70:30) at a flow rate of 1 mL/min and at a temperature of 25 °C. Regression analysis showed linearity at a detector wavelength of 290 nm in the range of 200-600 μg/mL for cefepime and 25-75 μg/mL for tazobactam. All of the analytes were adequately resolved with acceptable tailing. The percentage content found for cefepime was 99.98% and of tazobactam was 99.49% in the parenteral formulation. The method was validated in terms of linearity, precision, accuracy, specificity, robustness and system suitability according to ICH guidelines. Stress degradation studies were performed on the placebo and drug products, drugs of interest were well resolved from the degradation products. The developed method was effectively applied for the simultaneous quantification of cefepime and tazobactam in a dry injection formulation.


Desenvolveu-se método específico, preciso, exato, linear, rápido e econômico, de validação de estabilidade, indicando o método de CLAE-FR para a quantificação simultânea de cefepima e tazobactam na forma de dosagem injetável seca. A separação foi realizada em coluna C18 de ACE 5 mM com tampão fosfato, pH ajustado para 4,5 com ácido fosfórico:metanol (70:30), em fluxo de 1 mL/min e temperatura de 25 °C. A análise de regressão mostrou linearidade no detector de comprimento de onda de 290 nm, na faixa de 200-600 μg/mL, para cefepima, e 25-75 μg/mL, para tazobactam. Todos os analitos foram, adequadamente, resolvidos com cauda aceitável. O teor percentual encontrado na formulação parenteral foi de 99,98%, para cefepima, e de 99,49%, para o tazobactam. O método foi validado em termos de linearidade, precisão, exatidão, especificidade, robustez e adequação do sistema de acordo com as diretrizes ICH. Estudos de degradação por estresse foram realizados no grupo placebo e nos medicamentos e os fármacos de interesse foram bem resolvidos a partir dos produtos de degradação. O método desenvolvido foi efetivamente aplicado para quantificação simultânea de cefepima e tazobactam na formulação injetável seca.


Subject(s)
Metabolism , Chromatography, High Pressure Liquid/methods , Chemistry, Pharmaceutical/classification , Dosage/analysis
SELECTION OF CITATIONS
SEARCH DETAIL